Find the Correct Pipe Thread Size

Pipe threads and fitting sizes refer to the physical dimensions of the fittings but do not necessarily indicate the measurement of the pipe. Within the plumbing industry, the measurement of thread size is referred to as "nominal" pipe thread size, which indicates the inner diameter of the pipe size. This distinction can get confusing as the industry has several different terms that can be thrown around and if you're not sure what to measure and where you can end up with incorrectly sized fittings.

Let's begin by taking a look at a couple of NPT pipe fittings - NPT refers to as National Pipe Threads, which is a term defined by ANSI (American National Standards Institute). NPT fittings are the most common threads used for general purposes and feature tapered threads used for joining and sealing the fittings for use with fluids like air or gas.

NPT Threads

Measurement A shows the outside diameter (or OD) of the pipe fitting for a male fitting and Measurement B shows the top diameter of a female fitting. This measurement indicates the actual physical size of the fitting - using this measurement we can then correlate that size with its nominal pipe size (or NPS), which is more widely used. In the chart below you can find the physical measurements of the thread size (Col 1 and Col 2 are the same dimension) and cross reference it with the Pipe Thread Size in Col 3. Most often, when we say 1/2-inch in reference to a pipe size or fitting size, it references the nominal size - not the actual diameter shown in Measurement A & B.

US Pipe Thread Sizing Information
Col 1
(Dimension A)
Col 2
(Dimension A)
Col 3
(Dimension B)
Col 4
OD
Fraction Inch
OD
Decimal Inch
Pipe Thread Size
(Nominal Pipe Size)
Threads
per Inch
5/16 0.3125 1/16 27
13/32 0.405 1/8 27
35/64 0.540 1/4 18
43/64 0.675 3/8 18
27/32 0.840 1/2 14
1-3/64 1.050 3/4 14
1-5/16 1.315 1 11-1/2
1-21/32 1.660 1-1/4 11-1/2
1-29/32 1.900 1-1/2 11-1/2
2-3/8 2.375 2 11-1/2
2-7/8 2.875 2-1/2 8
3-1/2 3.5 3 8
4 4.0 3-1/2 8
4-1/2 4.5 4 8
5-5/8 5.563 5 8
6-5/8 6.625 6 8
8-5/8 8.625 8 8
10-3/4 10.75 10 8
12-3/4 12.75 12 8

 

 

Pipe Schedule

What causes confusion for many people, in or out of the industry, is the thickness of the pipe - which can vary even though the NPS stays the same. Referred to in the industry as Schedule, pipe thickness will indicate how thick the walls of the piping actually are while the inner diameter (or ID) is still the most common distinction for joining two fittings.

Threads per Inch or Thread Pitch

Measurement C shows the length of the threads themselves - when we take a closer look at these threads, we can actually measure the number of peaks and valleys to figure out the number of threads per inch (TPI) or the pitch of the threads. NPT threads have a 60° thread angle, the roots and crests are flat and the taper rate is 1 in 16 inch (which means the pipe size will drop 3/4-inch over 12-inches). To the left is a chart illustrating the most common TPI counts or thread pitch - pitch can be measured using this chart (print to actual size) or by using a thread gauge for more clarity.

Other Notes About Thread Sizing

In addition to those three main distinctions of threads, many acronyms are used throughout the industry - many incorrectly - and your fluency with the terms can help avoid confusion. As previously mentioned, NPT indicates the defined standard from ANSI - but many people use MPT/MIP and FPT/FIP interchangeably. MPT stands for Male Pipe Thread and MIP stands for Male Iron Pipe which both indicate a male fitting with NPT threads. FPT stands for Female Pipe Threads and FIP stands for Female Iron Pipe which both indicate a female fitting with NPT threads. Remember not to confuse NPS (again nominal pipe size) with National Pipe Size - which is NOT a real designation. Also, it's important to remember that if you don't feel comfortable measuring your fittings or pipe you should consult a professional - and always remember to make sure all of your projects are up to local codes and standards.