B

bongolia

Messages
9
I have to reconnect some 22mm copper to a section of grey 22mm polypipe fitted with Hepworth grey screw connectors with rubber o ring and plastic grab rings. All of the fittings have worked for over 10 years and still seem good. Acorn Engineering still sell them but I'll have to order and I'd like to get the job done yesterday. There is a final section of polypipe which will be a real pain to replace so I'd like to connect to this. Are there any easily available alternatives which will fit it? here's a pic:

You don't have permission to view attachments. Attachments are hidden.
 

Attachments

    You don't have permission to view attachments. Attachments are hidden.
J

joni os

Plumber
Messages
1,498
22mm compression couplings will do the job but be sure to use the stainless steel inserts. Copper olives on the plastic pipe are preferable to brass.
 
C

Ch4 plumbing

why not use either white Hep fittings or poly pipe fittings (which are grey)
 
E

ed209

Interesting you say SS inserts I spoke to Polypipe about this and they said plastic or SS inserts with compression
I now use the hp2o with the ridged inserts but still tend to use PP Tube as it still seems the most pliable
 
B

bongolia

Messages
9
Thanks everyone. I was just checking the viability of other products as there's quite a bit of noise about incompatibility between different manufacturers. There's also a fair bit of complaining about Hep joints failing a week or more after the installation. I've had these particular ones in place for over 10 years without problems but there are a number of people on this site who refuse to touch them. The bloke downstairs has just had a new bathroom done so I really don't wanna flood it just yet!
 
J

joni os

Plumber
Messages
1,498
SS inserts reduce available cross section much less than plastic and the plastic inserts with O rings should never be used with compression fittings.
 
A

AWheating

Plumber
Gas Engineer
Messages
9,872
All plastic push it work on 15 and 22 pipes, it's the inserts that are important. You need to use the pipe manufacturers inserts for there pipe, then use whatever fitting you can get.

Just don't use new hep inserts without hep fittings as the have a shaped end and on speedfit dont use the inserts with the o rings with other fittings Rd
 
Last edited:
Status
Not open for further replies.

Reply to Connection to old 22mm hepworth system. in the Plumbing Forum | Plumbing Advice area at PlumbersForums.net

Similar threads

P
For the benefit of anyone coming across this in the future who finds themselves in a similar situation, my plan (as outlined in post #25) worked a...
Replies
26
Views
877
Dec 10, 2021
Plumb Line
P
M
Current system Danesmoor utility installed in outbuilding. Flow/return connections on the boiler are each 1.5" BSP then straight into 32mm copper...
Replies
0
Views
197
M
M
In theory it's a simple job and while there may be some snagging involved (e.g. the fill valve in your toilet system may need replacing or...
Replies
3
Views
242
Dec 22, 2021
Ric2013
R
D
Looks like your attempting to put a plain 3/4 mi onto a tapered cone end . I would personally try to extract the other part of the union fitting...
Replies
3
Views
590
Sep 16, 2021
exedon2
P
Mr Speaker: I'm tempted to draught a sarcastic reply to the Right Honourable gentleman, but quite frankly it's a waste of time, as was the useful...
Replies
22
Views
357
Jan 24, 2022
Ric2013
R

Newest Threads (Please Reply)

Search Forum

Top