Hi,

I have a blocked 10mm pipe to a Towel Rad. I have both ends disconnected (distribution manifold and Rad) but cant get any flow through it. I have tried mains hose on to one end, but it seems to hold firm.

Its never works since I've been in the house (18 months) and the property is aprox 15 years old. There has been historic magnetite in the systems, but I have drained/filled it a couple of times when I moved in, I have been operating magnetic filters and used a course of X800 and have Inhibitors in normally.

Its not the only rad with a flow problem, but I'm addressing them one by one by flushing just the One Rad circuit at a time from the distribution manifolds. See picture.
You don't have permission to view attachments. Attachments are hidden.


Ant thoughts other than replace the pipe or replumb the house ;-) ?

Many thanks
 

Attachments

    You don't have permission to view attachments. Attachments are hidden.

Leo21

Plumber
Gas Engineer
Messages
9,323
Adapt a foot pump or compressed to fit it. 8mm is a snug fit, so you'd have to put 10mm to 15mm adapter on and then a 15mm to 8mm. And then pump away.
 

ShaunCorbs

Staff member
S. Mod
Plumber
Gas Engineer
Messages
29,714
Solutions
1
as above and watch your pressure tho

the only other way you could try is putting some cleaner do there and see if that weakens it
 
K

Kempfy

I've always found these with near boiling water is good for dislodging most sludge. Just be careful of fittings blowing off. (its not fun when they do that)
 

Attachments

    You don't have permission to view attachments. Attachments are hidden.
Last edited by a moderator:
B

bwel

Messages
48
I've always found these with near boiling water is good for dislodging most sludge. Just be careful of fittings blowing off. (its not fun when they do that)

What is the name of that device. I'd like to try that

Thx
 
K

Kempfy

Also adding fairy liquid and leaving it sit pressurised for a while seems to help.
 
B

bwel

Messages
48
Ok finally received my Pressure Tester courtesy of Amazon. :vanish:
You don't have permission to view attachments. Attachments are hidden.

i have it connected to the now disconnected 10mm feed from the 22mm 4 Port distribution manifold. The pipe runs use the floor and downstairs through the bathroom wall to the offending Towel Rad. I have also disconnected the check valve from the Rad so I have an open 10mm copper pipe with 15mm reducer.
You don't have permission to view attachments. Attachments are hidden.


When I pump the pressure tester I have had a small amount of water seep from the open 10mm pipe at the Rad, but it's losing pressure. I've taken it up to 15 bar, but no more for fear of blowing the plastic to copper joint behind the tilled wall. It very very slowly loses pressure but has not pushed the blockage out.

Any suggestions on the best way to deal with this ?

Many thanks....
 

Attachments

    You don't have permission to view attachments. Attachments are hidden.
Last edited:

scott_d

Plumber
Gas Engineer
Messages
5,818
Try pressurising from the other direction- towel rail end
 
B

bwel

Messages
48
Finally unlocked it !!

I repeatedly pressurised it up to 10 bar with the pressure tester. In each cycle it took a bit extra water that would drip drip out the end. I then switched the pressure tester water over to a bit of neat X800 to push that through to the blockage area.

Finally after a few hours of pushing it through, the pressure blew out a plug of black crystals and sludge. Fortunately it did not hit the bathroom ceiling

Now I've washed the heating loop through with mains water and it should be ready to reconnect tomorrow.

I think the pressure tester advise has saved a rip out of the pipework from the walls. Thx for all the advise.
 

ShaunCorbs

Staff member
S. Mod
Plumber
Gas Engineer
Messages
29,714
Solutions
1
And thank you for keeping us updated and letting us no your problem has been sorted
 
B

bwel

Messages
48
Had a bit of a leak on one of the 4 port Speedfit manifolds, but fixed that with a good cleaning and polishing the 22mm pipe.

You don't have permission to view attachments. Attachments are hidden.



I now have good heat flows in all but one of my rad circuits, except one rad. Fortunately the original Blocked Towel radiator is now working perfectly.

You don't have permission to view attachments. Attachments are hidden.

You don't have permission to view attachments. Attachments are hidden.


Whilst I have flushed it with mains water as well as X800 and thought it was heating well, it appears that there is some blockage. Does anybody know how this type of rad flows ?

Looks like I may have to remove it for a bit more of an aggressive cleaning process. Perhaps with a pressure washer in the garden.

P.S. the FLIR One thermal camera for the iPhone is amazing. Diagnoses any problems with flow and has enabled me to map my UFH circuits.

Cheers Bob
 

Attachments

    You don't have permission to view attachments. Attachments are hidden.
Last edited:

ShaunCorbs

Staff member
S. Mod
Plumber
Gas Engineer
Messages
29,714
Solutions
1
You don't have permission to view attachments. Attachments are hidden.


should be ok now
 

Attachments

    You don't have permission to view attachments. Attachments are hidden.
Status
Not open for further replies.

Reply to Blocked 10mm Speedfit Pipe to Towel Rad in the Central Heating Forum area at PlumbersForums.net

Similar threads

S
Ah, i hadn’t thought about the narrowing caused by inserts. That’s a very good point and makes me feel much better about using the Coldform joint...
Replies
10
Views
549
Jun 24, 2021
smallsteve
S
That must be the biggest load of crap I've heard on here.
Replies
27
Views
1K
Nov 20, 2021
SimonG
G
Thanks! I was thinking the same thing. New chrome valves, new pipe and new coupling have been ordered and are on their way. So like you said I...
Replies
15
Views
1K
Aug 17, 2021
geekyhiker
G
L
Sealed system now holding pressure get a decent flusher through it get it clean add inhibitor. Then have a crack at idiot who told you a heating...
Replies
10
Views
313
Jan 10, 2022
exedon2
M
All much of a much, (pretty good) centrifugal pumps, the stopped pump only builds up resistance if its impeller and ports are sludged up. Even...
Replies
3
Views
321
Oct 27, 2021
John.g
J

Newest Threads (Please Reply)

Search Forum

Top